Description
The Flexfilter EX is designed to withstand the overpressure of a potential explosion and is equipped with an explosion vent panel. The harmful effects of an explosion are minimized by releasing excess pressure and flames through this panel into a safe area. All Flexfilter EX modular components are fully electrically bonded and grounded. All electrical equipment is classified according to the EX dust explosive class. The module is equipped with either a standard 70-liter container with a pressure-balancing kit and a hopper, allowing the use of a conductive plastic bag for quick removal of collected dust, or a fully automatic discharge device with a conductive large bag and grounding cable for high-capacity dust extraction systems. The control filter allows the use of vacuum units not rated for explosive dust.
Permitted materials:
Understanding the properties of the material being removed is crucial. The FlexFilter EX is designed to collect material with the following properties:
— Dust explosion class: St1 and St2
— Pmax: ≤10 bar
— MIE (minimum ignition energy) > 1 mJ
— MIT (minimum ignition temperature)> 205 ° C
Product labeling:
FlexFilter EX — according to ATEX Directive 2014/34/EU is designated: II 3D Ex h IIIC T130ºC Dc
-10ºC≤Ta≤40ºC
Nederman 19.HB01X
- A modern filtration system to meet your current and future needs
- Equipped with an explosion relief panel
- Standard 70L tray with anti-static polyethylene bag or conductive bulk bag fitted to a fully automatic emptying device
- Designed for ISO 21904 compliance