Universal electronic control and monitoring device EXZT/IGZ

For single-line, multi-line and sequential lubrication systems

The IGZ 51 and EXZT universal electronic control and monitoring units are used in multi-line and sequential lubrication systems and are available in two supply voltages. These units are designed for stationary industrial equipment and can be installed in a control cabinet or inside a compact lubrication unit. They can be used as time- or pulse-dependent controllers to initiate the lubrication cycle. EXZT units monitor pump runtime and simultaneously monitor pulses from the pulse generator or metering sensor. All units are equipped with built-in functions tailored to customer requirements and can be configured to meet system requirements.

Technical characteristics and advantages

  • Combined universal control and monitoring device
  • Easy installation with U-shaped mounting rail
  • Adjustable operating modes
  • Timed response, depending on the load or stroke of the mechanism
  • The package includes a low level monitor and an EEPROM.

Application areas

  • Stationary industrial installations
  • Installation in a distribution cabinet for stationary equipment for general industrial purposes

Description

Technical specifications
Operating principle Universal electronic control and monitoring device
Operating temperature from 0 to +60 °C from +32 to +140 °F
Supply voltage 24VDC: -15/+10 %
Connector for class II
Protection class IP 30, clamps IP 20
Dimensions 70 × 75 × 110 mm 2.7 x 3.0 x 4.3 inches
Version +471
Input voltage 100-120VAC; 200-240VAC (±10 %)
Input current 70 mA / 35 mA
Input power 8 W
Frequency 50–60 Hz
Fuse max 6.3 A
Switching current max 5 A
Input voltage sensors 24 VDC
Version +472
Input voltage 20-24VDC; 20-24VAC (±10 %)
Nominal input current 75 mA with max. branching 250 mA
Input power 5 W
Nominal frequency DC or 50–60 Hz
Fuse max 6.3 A
Switching current max 5 A
Nominal input voltage 24 VDC
Ordering information 1)
For multi-line lubrication systems
Part number Input voltage Adjustable monitoring time Level monitoring Increasing the time interval Early warning about approaching a set level Pulse monitoring
IG351-10-E+471 120, 230 V DC current Normally open
IG351-10-E+472 24 V AC Normally open
EXZT2A03-E+471 120, 230 V DC current Normally closed
EXZT2A03-E+42 24 V AC Normally closed
Ordering information 1)
For sequential lubrication systems
Part number Input voltage Adjustable pump delay time Pulse monitoring (time interval) Pre-lubrication Storing power failure information in memory
EXZT2A03-E+471 100-120; 200-240 VAC
EXZT2A03-E+472 20-24 VDC
EXZT2A06-E+471 100-120; 200-240 VAC
EXZT2A06-E+472 20-24 VDC
IGZ 51-20-E+471 100-120; 200-240 VAC
IGZ 51-20-E+472 20-24 VDC
IGZ 51-20-S2-E+471 100-120; 200-240 VAC
IGZ 51-20-S2-E+472 20-24 VDC
IGZ 51-20-S7-E+471 100-120; 200-240 VAC
IGZ 51-20-S7-E+472 20-24 VDC
IGZ 51-20-S8-E+471 100-120; 200-240 VAC
IGZ 51-20-S8-E+472 20-24 VDC
Ordering information 1)
For single-line lubrication systems
Part number Input voltage Adjustable monitoring time Adjustable pump delay time Pressure relief monitoring Level monitoring Increasing the time interval Early warning about approaching a set level Pulse monitoring Storing power failure information in memory
EXZT2A02+471 120 VDC Normally open Normally open
EXZT2A02+472 24 V AC Normally open Normally open
EXZT2A05+471 120 VDC Normally closed
EXZT2A05+472 24 V AC Normally closed
EXZT2A07+471 120 VDC Normally closed
EXZT2A07+472 24 V AC Normally closed
IGZ36-20+471 120 VDC Normally closed Normally open
IGZ36-20+472 24 V AC Normally closed Normally open
IGZ36-20-S6+471 120 VDC Normally closed Normally closed
IGZ36-20-S6+472 24 V AC Normally closed Normally closed
IGZ38-30+471 120 VDC Normally closed
IGZ38-30+472 24 V AC Normally closed
IGZ38-30-S1+471 120 VDC Normally open
IGZ38-30-S1+472 24 V AC Normally open
IGZ51-20-S3+471 120 VDC Normally closed Normally open
IGZ51-20-S3+472 24 V AC Normally closed Normally open