Type EW-PAP (with metal braiding)

EW-PAP cable protection conduits are made of specially modified polyamide 6 and braided with galvanized steel wire. These materials are halogen-, phosphorus-, and cadmium-free.

EW-PAP cable protection conduits feature excellent compressive strength and reliable thermal and mechanical protection. These conduits are used in mechanical engineering, for example, in automatic welding equipment or in areas where hot chips come into contact with machining centers. They are also used in systems requiring EMC protection.

For static applications under medium to high mechanical loads.

Application:

  • Systems requiring EMC
  • In the area of hot metal shavings
  • in the field of welding.
SKU: 182282 Category:

Description

Options

Name GTIN Article
EW-PAP-M12/P09: Gray 4045005195524 83141010
EW-PAP-M16/P11: Gray 4045005059024 83141012
EW-PAP-M20/P16: Gray 4045005067197 83141014
EW-PAP-M25/P21: Gray 4045005259967 83141016
EW-PAP-M32/P29: Gray 4045005230553 83141018
EW-PAP-M40/P36: Gray 4045005112866 83141020
EW-PAP-M50/P48: Gray 4045005267962 83141022

 

Additional details

Type of product Order number Color A Ø mm B Ø mm Static radius mm Weight kg/100 m Qty. m

EW-PAP-M12/P09

83141010

Grey

9.8

14

37

14.0

50

EW-PAP-M16/P11

83141012

Grey

12.3

16.8

58

16.0

50

EW-PAP-M20/P16

83141014

Grey

15.8

22

81

20.0

50

EW-PAP-M25/P21

83141016

Grey

22.4

29.4

95

36.0

50

EW-PAP-M32/P29

83141018

Grey

27.5

35.5

118

36.0

25

EW-PAP-M40/P36

83141020

Grey

35.5

43.5

162

50.0

25

EW-PAP-M50/P48

83141022

Grey

46.5

55.5

208

62.0

25