Description
| Operating principle | flow limiter | |
| Outlet pipes | 1 | |
| Lubricant | environmentally friendly mineral and synthetic oils | |
| Viscosity | 20–600 mm2/With | |
| Consumption1) | 25–90 l/min | 52.8–190 pints/min |
| Operating temperature | from 0 to 100 °C | from 32 to 212 °F |
| Working pressure 2) | 5–200 bar | 72–2900 psi |
| Differential pressure | >5 bar | >72 psi |
| Material | gray cast iron, galvanized | |
| Input connection | M12×1; four-pin connector | |
| Protection class | IP 65 | |
| Signal sensors E4/E5 | 24V to 230V AC/DC; IP 65 | |
| E6 proximity switch | 12 to 36 V DC current; IP 67 | |
| Dimensions | min. 40 × 90 × 138 mm max. 40 × 90 × 245 mm |
1.57 x 3.54 x 5.43 inches 1.57 x 3.54 x 9.63 inches |
| Installation position | any, preferably vertical | |
| The product can be configured using a configuration code. The flow rate must be adjusted according to the insert nozzle size, as shown in the table below. | |
| 24-2706-0… 24-2706-1… |
SMB06 without monitoring, plug-in nozzle size = see table below |
| 24-2706-6… 24-2706-7… |
SMB06 with E6 piston sensor, insert nozzle size = see table below |
| 24-2706-8… 24-2706-9… |
SMB06 with E4 signal transmitter, insert nozzle size = see table below |
| 24-2706-44… 24-2706-55… |
SMB06 with signal transmitter E5, plug-in nozzle size = see table below |
| ATEX versions are available upon request, ATEX only (EX II 3cII CT6), without monitoring, or with an E5 signal transmitter. Please add "ATEX" to the end of the part number. For more information, see the product catalog. | |
| Article | Consumption | Injector index | Nozzle | |
| l/min | pints/min | ∅ mm | ||
| 44-0455-2357 | 25 | 52,8 | 570 | 5,7 |
| 44-0455-2360 | 30 | 63,4 | 630 | 6,3 |
| 44-0455-2363 | 35 | 73,9 | 680 | 6,8 |
| 44-0455-2365 | 40 | 84,5 | 730 | 7,3 |
| 44-0455-2367 | 45 | 95,1 | 780 | 7,8 |
| 44-0455-2369 | 50 | 105,7 | 820 | 8,2 |
| 44-0455-2371 | 55 | 116,2 | 870 | 8,7 |
| 44-0455-2373 | 60 | 126,8 | 910 | 9,1 |
| 44-0455-2374 | 65 | 137,4 | 960 | 9,6 |
| 44-0455-2375 | 70 | 147,9 | 000 | 10,0 |
| 44-0455-2376 | 75 | 158,5 | 040 | 10,4 |
| 44-0455-2377 | 80 | 169,0 | 080 | 10,8 |
| 44-0455-2378 | 90 | 190,2 | 170 | 11,7 |
| Article | Description |
| 24-0404-2155 | Seal kit |
| 24-1072-2113 | E4 signal transmitter without contact connector |
| 24-1072-2115 | E4 Signal Transmitter with Contact Connector, with LED 24VDC |
| 24-1882-2151 | E4 connector with 24VDC LED |
| 24-1072-2113 | E5 signal transmitter without contact connector |
| 24-1072-2114 | E5 Signal Transmitter with Contact Connector, Without LED 24VDC |
| 24-1882-2121 | E5 with contact connector, without LEDs |
| 24-1884-2282 | Piston sensor E6 |
| 179-990-371 | straight connector, four-pin, M12×1 |
| 179-990-372 | angular connector, four-pin, M12×1 |
| 179-990-600 | straight connector, four-pin, M12×1, with 5 m orange cable |
| 179-990-601 | Angled connector, four-pin, M12×1, with 5 m orange cable |
| 84-8011-0369 | group monitoring unit |
| Part number | Description |
| 24-0712-6050 | SMB 6 without injector, without signal transmitter |