Technical characteristics and advantages

  • Three versions with dosing ranges from 0 to 180 l/min (0 to 380 pints/min)
  • Durable aluminum body
  • Inspection window for visual inspection
  • Gear-based measurement principle

Application areas

  • Circulating oil lubrication systems
  • Pulp and paper industry
  • Metallurgy
  • Mining
  • Mining and processing industry
  • Cement industry
  • Presses for stamping car body parts

Documentation

Category:

Description

Technical specifications
Operating principle gear indicator
Lubricant mineral and synthetic oils
viscosity 20–600 mm2/With
Operating temperature from 0 to +70 °C from +32 to 158 °F
Working pressure 6–50 bar 87–725 psi
Consumption
   SFZ 9E30/1 6–30 l/min 12.7–63.4 pints/min
   SFZ 9E100/1 25–132 l/min 52.8–279 pints/min
   SFZ 9E180/3 25–180 l/min 52.8–380 pints/min
Electrical connection Hall sensor
Voltage 24 V DC current ±10 %; 20 mA
Material Al, Cu, Mg, Pb
Protection class IP 65
Dimensions min. 80 × 80 × 75 mm
max. 190 × 180 × 150 mm
min. 3.1 x 3.1 x 3.0 inches
max 190 x 180 x 150 inches
Installation position any
Ordering information
Part number Designation Monitoring Compound Consumption
l/min pints/min
24-2581-2150 SFZ 9/6/1 visual G 3/8 0.09–8.2 0.19–17.3
24-2581-2151 SFZ 9E/6/1 electric G 3/8 0.09–8.2 0.19–17.3
24-2581-2155 SFZ 9E30/1 electric G 3/4 6-30 12,7-63,4
24-2581-2156 SFZ 9E100/1 electric G 1 1/4 25-132 52,8-279
24-2581-2550 SFZ 9E180/3 electric G 1 1/4 max 180 max 380