LGEP 1 - Extreme Pressure Grease

Categories: ,

Description

SKF LGEP 1 is a high-viscosity, low-consistency mineral oil-based grease with a lithium-calcium thickener. Ideal for lubricating large bearings operating under heavy loads and low speeds, LGEP 1 was developed to extend maintenance intervals and minimize downtime.

Features and Benefits

  • Excellent mechanical stability
  • Very good protection against abrasion and wear
  • Good fluidity at low initial temperature
  • Good flow properties allow easy replenishment of grease in the bearing structure.
  • Low friction characteristics help maintain low operating temperatures
  • Excellent water resistance and corrosion protection
  • Good pumpability

Typical applications

  • Wind turbine main shaft bearings
  • Large bearing applications
  • Heavy industry
  • Centralized lubrication systems
Available pack sizes
Packsize Designation
18 kg pail LGEP 1/18
Technical specifications
Designation LGEP 1/(container volume)
Code according to DIN 51825 KP1K-20
NLGI consistency class 1
Thickener Lithium-calcium
Color Beige
Base oil type Mineral
Operating temperature range from −20 to +120 °C (from −4 to +248 °F)
Dropping point according to DIN ISO 2176 min. 170 °C (min. 338 °F)
Base oil viscosity 40 °C, mm2/With 400
100 °C, mm2/With 25
Penetration according to DIN ISO 2137 60 dives, 10-1 mm 310–340
100,000 dives, 10-1 mm max +50
Mechanical stability Rolling stability, 50 h at 80 °C, 10-1 mm max +50
Corrosion protection
Emcor: – ISO 11007 standard 0–0
– water washout test 0–0
– salt water test (1 % NaCl) 0–0
Water resistance to DIN 51 807/1, 3 h at 90 °C max 1
Oil separation according to DIN 51 817, 7 days at 40 °C, static, % 1–5
Lubricity R2F, test B at 120°C Positive result at 80°C
Copper corrosion according to DIN 51 811, 120 °C max 1
Service life of rolling bearing greases L-life test50 on the R0F machine at 10,000 rpm, h min. 1000 at 100 °C
Anti-seize properties Wear test according to DIN 51350/5, 1400 N, mm max 1.8
Four-ball test, welding load according to DIN 51350/4. N min. 3400
These characteristics represent typical values.

 

Download PDF