Description
Operating principle
| Operating principle | dosing device 1) | |
| Exits | from 1 to 6 | |
| Dosage volume | 0.25–1.31 cm³ | 0.015–0.08 in³ |
| Lubricant | plastic lubricants up to NLGI 0, 1, 2 inclusive | |
| Operating temperature | max. +82 °C | max +180 °F |
| Working pressure | 128–413 bar typical: 172 bar |
1850–6000 psi typical: 2500 psi |
| Relief pressure | 70 bar | 1000 psi |
| Material | carbon steel | |
| Connection of the main pipeline | 3/8 NPTF (F) | |
| Output connection | 1/8 NPTF (F) | |
| Dimensions | min. 63 × 222 × 35 mm max. 203 × 222 × 35 mm |
min. 2.5 x 8.7 x 1.4 inches max 6.1 x 8.7 x 1.4 inches |
| Installation position | any | |
| Part number | Designation | Number of outputs |
| 85770–1 | SL-V mounting panel with one dosing device | 1 |
| 85770–2 | SL-V mounting panel with two dosing devices | 2 |
| 85770–3 | SL-V mounting panel with three dosing devices | 3 |
| 85770–4 | SL-V mounting panel with four dosing devices | 4 |
| 85770–5 | SL-V mounting panel with five dosing devices | 5 |
| 85770–6 | SL-V mounting panel with six dosing devices | 6 |
| 85771 | Replacement for dosing unit with mounting panel | — |
| 85772 | Single Dispenser, No Mounting Panel, 3/8 NPTF (M) | — |