CLP Touch
For use in progressive lubrication systems
CLP Touch pumps come with an integrated control board with data-logging functionality. Using the intuitive touch panel makes it very easy to set pump parameters. The CLP Touch version provides an integrated control board with a touch panel that allows users to configure the pump easily and intuitively.
The user is guided through the parameter settings. In case of pump or system failures, the panel provides full-text messages in many languages. Users can easily monitor the operational status thanks to the visual red/green indication.
An integrated datalogger provides a performance and failure log, which allows for checking if the machine is appropriately lubricated. It makes it easier for users to plan the next refill of the pump, as the datalogger provides a prewarning signal and indicates the remaining time to refill based on the usage.
The touch panel is protected against dirt and unauthorized settings.
By offering three operation modes (time, counter and progressive cycle controlled), CLP Touch pumps provide need-based lubrication for any application.
Features and benefits
- Easy and intuitive setting of pump configuration
- Guided set up of pump parameters
- Prevents misuse or unintended changes by password protection on different levels
- Greater visibility to track machine health data
- Early warning of potential failures to take preventive action
- Full-text display of failures and other events
- Visual indication of operational status
Applications
- Small progressive lubrication systems
- Mobile versions:
- Construction machinery
- Farm machinery
- Bus
- Trucks
 
- Industrial versions:
- Food and beverage equipment
- Packaging lines
- Elevators
- Conveyors
- Centrifuges
- Wind turbines
- Cranes
 
Documentation
Description
| Function principle | Electrically operated lubrication pump | |
| Lubricant | Greases: NLGI 0 to NLGI 2 | |
| Max. working pressure | 270 bar | 3,916 psi | 
| Operating temperature | -25 to +65°C | -13 to +149°F | 
| Usable reservoir volume | 1 l | 0.26 gal | 
| Number of pump elements | max. 2 | |
| Pump element 1) | 6 | |
| Lubricant output 2) | ~3 cm3/min | |
| IP protection class 3) | IP 6K9K | |
| Corrosion class | C3 | |
| Voltages | 12/24 V DC | |
| Operating current | up to 3 A (max. peak), nominal 1.2 A | |
| Relative duty cycle | 15% ED S3 30 minutes | |
| Electrical protection class | III | |
| Outlet connection | G1/4 | |
| Mounting position | upright | |
| Dimensions (max. H×W×D4)) | 235×187×190 mm | 8.34×7.36×7.48 in | 
| Weight (empty) | 5 kg | 11 pounds | 
| Order code | Application | Features | |
| CLP-EG1AT1-0000061 |  | Mobile use, 12 V | 
 | 
| CLP-EG1AT2-0000062 |  | Mobile use, 24 V | 
 | 
| CLP-XG1AT2-0000063 |  | Industrial use, 24 V | 
 | 
| CLP-EG1AT1-0000068 |  | Mobile use, 12 V | 
 | 
| CLP-EG1AT2-0000069 |  | Mobile use, 24 V | 
 | 
Spare parts / Accessories
| Order number | Description | Nominal output | |
| cm3/min | in3/min | ||
| 600-26875-2 | Pump element 5 | 1.8 | 0.11 | 
| 600-26876-2 | Pump element 6 | 2.8 | 0.17 | 
| 600-26877-2 | Pump element 7 | 4 | 0.24 | 
| 655-28716-1 | Pump element R | 0.7-3.3 | 0.04-0.02 | 
| Order number | Description | 
| 519-33840-1 | Adapter with lubrication fitting ST 1/4 NPTF | 
| 519-33959-1 | Adapter with lubrication fitting A2 AR 1/4 | 
| 519-33955-1 | Adapter with lubrication fitting ST AR 1/4 | 
| 519-60445-1 | Closure screw M22x 1.5 | 
| Order number | Description | 
| 270864 | SVTSV-270-R1/4-1/8NPTFI-NIP00R-A | 
| 624-77803-1 | SVTSV-270-R1/4-6-NIP00L | 
| 624-77802-1 | SVTSV-270-R1/4-6-NIP00R | 
| Order number | Description | 
| 664-34167-9 | Bayonet socket, 4 poles with cable 10 m | 
| 664-34428-3 | Bayonet socket, 7 poles with cable 10 m | 
| 664-35078-9 | Square socket with 10 m cable | 
| Order number | Description | 
| 5590-00000002 | Filling connection cartridge | 
| 5590-00000015 | Mounting bracket kit | 
| 5590-00000014 | Venting kit | 