{"id":7576,"date":"2025-02-14T15:33:47","date_gmt":"2025-02-14T12:33:47","guid":{"rendered":"https:\/\/titan.ziz.kz\/?post_type=product&#038;p=7576"},"modified":"2025-07-28T16:44:54","modified_gmt":"2025-07-28T13:44:54","slug":"mnogotochechnye-avtomaticheskie-lubrikatory","status":"publish","type":"product","link":"https:\/\/tpgt.kz\/en\/product\/mnogotochechnye-avtomaticheskie-lubrikatory\/","title":{"rendered":"Multi-point automatic lubricators: Reliable lubrication of multiple points"},"content":{"rendered":"<section class=\"sections\">\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-489847\" class=\"col-md-12 space-between\">\n<div class=\"highlighted-content row\">\n<div class=\"col-md-12 col-xl-4\">\n<div class=\"box-text bg-cool-grey\">\n<div class=\"description\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-476940\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" border=\"1\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Product Information<\/caption>\n<colgroup>\n<col width=\"40%\" valign=\"top\" \/>\n<col width=\"60%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td>\n<ol>\n<li>Durable metal housing for long service life<\/li>\n<li>Grease nipple<\/li>\n<li>LED display for easy programming<\/li>\n<li>Alarm for empty tank or blocked outlet<\/li>\n<li>Filter to prevent contamination of plastic lubricant with airborne particles<\/li>\n<li>A device for mixing to ensure the homogeneity of plastic lubricant<\/li>\n<li>Maximum pump working pressure 205 bar (2970 psi)<\/li>\n<li>The block distributor provides flexibility for use from 1 to 8 outlets<\/li>\n<li>The cycle control sensor ensures that lubricant is supplied to the outlets<\/li>\n<\/ol>\n<\/td>\n<td><img decoding=\"async\" data-src=\"https:\/\/www.skf.com\/binaries\/pub12\/Images\/TLMP_tcm_12-289350.jpg\" data-aspect=\"0\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"flexible-text bg-light-green text-light-black\">\n<div class=\"img-container\">\n<div>\n<div class=\"video-wrapper\">\n<div class=\"wrapper\">\n<div class=\"play-container\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div id=\"cid-476945\" class=\"bg-off-white make-sticky\">\n<div id=\"top-target-div-8589935b-06f5-40b2-a6eb-9ca5557a987a\" class=\"anchor\">\n<div id=\"toMoveID\" class=\"toMove maxHeight\">\n<div class=\"container\">\n<div class=\"content is-not-pdp\">\n<div id=\"heightChecker\" class=\"shortcuts is-not-pdp\">\n<div class=\"progress-container\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-476941\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" border=\"1\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Equipment<\/caption>\n<tbody>\n<tr>\n<td colspan=\"3\">The TLMP series lubricators are supplied complete with the following components:<\/td>\n<\/tr>\n<tr>\n<td><strong>TLMP 1008<\/strong><\/td>\n<td><strong>TLMP 1018<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>1<\/td>\n<td>Pump<\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>1<\/td>\n<td>Fittings for pump unit<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>2<\/td>\n<td>Electrical connectors<\/td>\n<\/tr>\n<tr>\n<td>20 m (65 ft)<\/td>\n<td>50 m (164 ft)<\/td>\n<td>Plastic tubing, nylon, 6 x 1.5 mm<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>18<\/td>\n<td>Straight pipe connections for G 1\/8 thread<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>18<\/td>\n<td>Plugs for pipe connections<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>17<\/td>\n<td>Plugs for outlets<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"cid-501485\" class=\"col-md-4 space-between\">\n<div class=\"releated-links\">\n<div class=\"content\">\n<div><\/div>\n<div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-476942\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" border=\"1\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Technical specifications<\/caption>\n<tbody>\n<tr>\n<td valign=\"top\"><strong>Designation<\/strong><\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><strong>TLMP 1008 \/ TLMP 1018<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\">Number of lubricant outlets<\/td>\n<td valign=\"top\">TLMP 1008<\/td>\n<td valign=\"top\">1\u20138<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">TLMP 1018<\/td>\n<td valign=\"top\">1\u201318<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Suitable consistency of lubricant<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">NLGI 2, 3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Maximum pressure<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">205 bar (2970 psi)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Maximum distance to lubrication point<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">5 m (16 ft)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Lubricant consumption<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">0.1\u201340 cc\/day (0.003\u20131.35 US fl oz\/day) per output<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Pump element performance<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Approx. 0.2 cm3 (per cycle), approx. 1.7 cm3 (per minute)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Tank capacity<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">1 liter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Useful volume of the tank<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Approx. 0.5\u20130.9 L (17\u201330 US fl oz)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Filling<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Through hydraulic fitting R1\/4<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Installation position<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Vertical (max. deviation \u00b15\u00b0)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power connector<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">EN 175301-803, DIN 43650\/A<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Signaling<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Blocking of pipelines, emptying of the tank<br \/>\ninternal and external<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">External management<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">By turning off the power supply<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Ambient temperature<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">from \u221225 to +70 \u00b0C (from \u221213 to +160 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">IP protection class<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">IP 67<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"top\">Pipelines<\/td>\n<td valign=\"top\">TLMP 1008<\/td>\n<td valign=\"top\">20 m (65 ft) 6 x 1.5 mm nylon<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">TLMP 1018<\/td>\n<td valign=\"top\">50 m (164 ft) 6 x 1.5 mm nylon<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Weight<\/td>\n<td valign=\"top\"><\/td>\n<td valign=\"top\">Approx. 6 kg (13 lbs)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\">Order details, 8 outputs<\/td>\n<td valign=\"top\">TLMP 1008\/24DC<\/td>\n<td valign=\"top\">24 V DC current (\u221220 to +30 %)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">TLMP 1008\/120V<\/td>\n<td valign=\"top\">120 VAC, 60 Hz (\u00b110 %)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">TLMP 1008\/230V<\/td>\n<td valign=\"top\">230 V AC, 50 Hz (\u00b110 %)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\">Order details, 18 outputs<\/td>\n<td valign=\"top\">TLMP 1018\/24DC<\/td>\n<td valign=\"top\">24 V DC current (\u221220 to +30 %)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">TLMP 1018\/120V<\/td>\n<td valign=\"top\">120 VAC, 60 Hz (\u00b110 %)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">TLMP 1018\/230V<\/td>\n<td valign=\"top\">230 V AC, 50 Hz (\u00b110 %)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-476943\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" border=\"1\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Accessories<\/caption>\n<tbody>\n<tr>\n<td><strong>Designation<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td>LAGF 1-F<\/td>\n<td>Flexible hose with filling fitting<\/td>\n<\/tr>\n<tr>\n<td>LAGF 1-H<\/td>\n<td>Filling fitting<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-476944\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" border=\"1\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Spare parts<\/caption>\n<tbody>\n<tr>\n<td><strong>Designation<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-D8<\/td>\n<td>TLMP SSV 8 K rear mounted dosing unit<\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-D18<\/td>\n<td>TLMP SSV 18 K rear mounted dosing unit<\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-F<\/td>\n<td>Sponge filter for TLMP<\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-P<\/td>\n<td>Pump element D6 for TLMP<\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-R<\/td>\n<td>Transparent tank (1 l) with seal and stickers for TLMP<\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-H<\/td>\n<td>Housing cover repair kit for TLMP<\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-M24<\/td>\n<td>Pump Motor, 24VDC, for TLMP<\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-C24<\/td>\n<td>24VDC Control PCB Repair Kit for TLMP<\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-C120<\/td>\n<td>120VAC Control PCB Repair Kit for TLMP<\/td>\n<\/tr>\n<tr>\n<td>TLMP 1-C230<\/td>\n<td>230V AC Control PCB Repair Kit for TLMP<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<div class=\"content-area col-lg-5\">\n<h1 class=\"title title-desktop title-active\"><span style=\"font-size: 16px;\">Reliable lubrication of multiple points<\/span><\/h1>\n<div class=\"description\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p>The SKF TLMP Series Automatic Multi-Point Lubricator is designed for relubricating multiple lubrication points. This robust automatic lubrication system is supplied as a complete kit, including the lubricator, necessary piping, and connections. The TLMP Series Lubricator is designed to deliver lubricant to multiple lubrication points (1 to 18). It features lockable outlets, easy connection, and programming via a keypad with an LED display.<\/p>\n<p>This universal lubricator has a reservoir capacity of approximately 1 liter. It is equipped with a mixing device to maintain a homogeneous lubricant, making it suitable for most types of lubricant. The reliable TLMP series lubricator has a high IP rating, allowing it to withstand vibration and equipment washdowns, as well as protect against contaminants. This unit also allows you to stop the lubricant flow by disconnecting the power supply.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"columns\">\n<div class=\"column-one\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p class=\"small-capital-heading\">Technical characteristics and advantages<\/p>\n<ul>\n<li>Easy to install and program<\/li>\n<li>Comes fully assembled<\/li>\n<li>Suitable for lubrication from 1 to 18 points<\/li>\n<li>Alarm for malfunctions and low lubricant levels, remote notifications possible<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"column-two\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<ul>\n<li>Stopping the lubricant supply by turning off the power<\/li>\n<li>Versions with different supply voltages are available<\/li>\n<li>Designed for industrial, agricultural and off-road applications<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"featured_media":7556,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[11545,1613],"product_tag":[],"class_list":{"0":"post-7576","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-lubrikatory","7":"product_cat-motornye-masla","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product\/7576","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media\/7556"}],"wp:attachment":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media?parent=7576"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_brand?post=7576"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_cat?post=7576"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_tag?post=7576"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}