{"id":6794,"date":"2025-02-12T13:24:31","date_gmt":"2025-02-12T10:24:31","guid":{"rendered":"https:\/\/titan.ziz.kz\/?post_type=product&#038;p=6794"},"modified":"2025-08-14T13:28:48","modified_gmt":"2025-08-14T10:28:48","slug":"perekljuchajushhij-klapan-maxilube","status":"publish","type":"product","link":"https:\/\/tpgt.kz\/en\/product\/perekljuchajushhij-klapan-maxilube\/","title":{"rendered":"Maxilube switching valve"},"content":{"rendered":"<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-483937\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"Part numbers\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Technical specifications<\/caption>\n<colgroup>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td>Operating principle<\/td>\n<td colspan=\"2\" align=\"left\">electropneumatic changeover valve<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>0\u201350 \u00b0C<\/td>\n<td><em>32\u2013122\u00b0F<\/em><\/td>\n<\/tr>\n<tr>\n<td>Working pressure<\/td>\n<td>max 300 bar<\/td>\n<td><em>4350 psi<\/em><\/td>\n<\/tr>\n<tr>\n<td>Air supply pressure<\/td>\n<td>2.0\u20134.5 bar<\/td>\n<td><em>29\u201365 psi<\/em><\/td>\n<\/tr>\n<tr>\n<td>Air flow<\/td>\n<td>max 300 l\/min<\/td>\n<td><em>80 gallons\/min<\/em><\/td>\n<\/tr>\n<tr>\n<td>Lubricant<\/td>\n<td colspan=\"2\" align=\"left\">plastic grease: up to and including NLGI 2<br \/>\noil: 5000 mm<sup>2<\/sup>\/With<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\">Electrical connections<\/td>\n<\/tr>\n<tr>\n<td align=\"right\">Control voltage<\/td>\n<td colspan=\"2\" align=\"left\">24 VDC<\/td>\n<\/tr>\n<tr>\n<td align=\"right\">Power supply<\/td>\n<td colspan=\"2\" align=\"left\">115\/230 VAC, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Protection class<\/td>\n<td colspan=\"2\" align=\"left\">IP 65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" align=\"left\">Dimensions depending on the model<\/td>\n<\/tr>\n<tr>\n<td align=\"right\">min.<\/td>\n<td>650 x 130 x 130 mm<\/td>\n<td><em>25.6 x 5.12 x 5.12 inches<\/em><\/td>\n<\/tr>\n<tr>\n<td align=\"right\">Max.<\/td>\n<td>1020 x 130 x 130 mm<\/td>\n<td>40.16 x\u00a0<em>5.12 x 5.12 inches<\/em><\/td>\n<\/tr>\n<tr>\n<td>Installation position<\/td>\n<td colspan=\"2\" align=\"left\">vertical<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-483936\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"Ordering information\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Ordering information<\/caption>\n<colgroup>\n<col width=\"15%\" valign=\"top\" \/>\n<col width=\"25%\" valign=\"top\" \/>\n<col width=\"60%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td><strong>Part number<\/strong><\/td>\n<td><strong>Designation<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>12371171<\/strong><\/td>\n<td><strong>MAX-1-2-230-IF105-R-V2<\/strong><\/td>\n<td>Single-channel, dual-line lubrication system, 230 VAC, with control unit, \u00f8 12 mm line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371501<\/strong><\/td>\n<td><strong>MAX-1-2-230-IF105-U-V2<\/strong><\/td>\n<td>Single-channel dual-line lubrication system, 230 VAC, with control unit, 1\/2&quot; \u00f8 line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371041<\/strong><\/td>\n<td><strong>MAX-1-2-115-IF105-R-V2<\/strong><\/td>\n<td>Single-channel, dual-line lubrication system, 115 VAC, with control unit, \u00f8 12 mm line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371371<\/strong><\/td>\n<td><strong>MAX-1-2-115-IF105-U-V2<\/strong><\/td>\n<td>Single-channel, dual-line lubrication system, 115 VAC, with control unit, 1\/2&quot; line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371175<\/strong><\/td>\n<td><strong>MAX-1-2-24-IF105-R-V2<\/strong><\/td>\n<td>Single-channel, dual-line lubrication system, 24 VDC, with control unit, line outlets \u00f8 12 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>12371231<\/strong><\/td>\n<td><strong>MAX-2-2-230-IF105-R-V2<\/strong><\/td>\n<td>Dual-channel, dual-line lubrication system, 230 VAC, with control unit, \u00f8 12 mm line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371561<\/strong><\/td>\n<td><strong>MAX-2-2-230-IF105-U-V2<\/strong><\/td>\n<td>Dual-channel, dual-line lubrication system, 230 VAC, with control unit, 1\/2&quot; \u00f8 line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371101<\/strong><\/td>\n<td><strong>MAX-2-2-115-IF105-R-V2<\/strong><\/td>\n<td>Dual-channel, dual-line lubrication system, 115 VAC, with control unit, \u00f8 12 mm line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371431<\/strong><\/td>\n<td><strong>MAX-2-2-115-IF105-U-V2<\/strong><\/td>\n<td>Dual-channel, dual-line lubrication system, 115 VAC, with control unit, 1\/2&quot; line outlets<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>12371141<\/strong><\/td>\n<td><strong>MAX-1-1-230-IF105-R-V2<\/strong><\/td>\n<td>Single-channel, single-line or sequential lubrication system, 230 VAC, with control unit, line outlets \u00f8 12 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>12371471<\/strong><\/td>\n<td><strong>MAX-1-1-230-IF105-U-V2<\/strong><\/td>\n<td>Single-channel, single-line or sequential lubrication system, 230 VAC, with control unit, 1\/2&quot; \u00f8 line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371011<\/strong><\/td>\n<td><strong>MAX-1-1-115-IF105-R-V2<\/strong><\/td>\n<td>Single-channel, single-line or sequential lubrication system, 115 VAC, with control unit, \u00f8 12 mm line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371341<\/strong><\/td>\n<td><strong>MAX-1-1-115-IF105-U-V2<\/strong><\/td>\n<td>Single-channel, single-line or sequential lubrication system, 115 VAC, with control unit, 1\/2&quot; line outlets<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>12371201<\/strong><\/td>\n<td><strong>MAX-2-1-230-IF105-R-V2<\/strong><\/td>\n<td>Dual-channel, single-line or sequential lubrication system, 230 VAC, with control unit, \u00f8 12 mm line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371531<\/strong><\/td>\n<td><strong>MAX-2-1-230-IF105-U-V2<\/strong><\/td>\n<td>Dual-channel, single-line or sequential lubrication system, 230 VAC, with control unit, \u00f8 12 mm line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371071<\/strong><\/td>\n<td><strong>MAX-2-1-115-IF105-R-V2<\/strong><\/td>\n<td>Dual-channel, single-line or sequential lubrication system, 115 VAC, with control unit, \u00f8 12 mm line outlets<\/td>\n<\/tr>\n<tr>\n<td><strong>12371401<\/strong><\/td>\n<td><strong>MAX-2-1-115-IF105-U-V2<\/strong><\/td>\n<td>Dual-channel, single-line or sequential lubrication system, 115 VAC, with control unit, \u00f8 12 mm line outlets<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>12371271<\/strong><\/td>\n<td><strong>MAX-1-2-24-XR-V2<\/strong><\/td>\n<td>Single-channel dual-line lubrication system, 24 VDC, without control unit, line outlets \u00f8 12 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>12371601<\/strong><\/td>\n<td><strong>MAX-1-2-24-XU-V2<\/strong><\/td>\n<td>Single-channel dual-line lubrication system, 24 VDC, without control unit, line outlets \u00f8 1\/2 inch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-494481\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>SMS monitoring and control unit<\/caption>\n<colgroup>\n<col width=\"25%\" valign=\"top\" \/>\n<col width=\"25%\" valign=\"top\" \/>\n<col width=\"50%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td rowspan=\"3\" bgcolor=\"#FFFFFF\"><img decoding=\"async\" title=\"skf.com-0901d1968090502d-E-SMS-C\" data-src=\"https:\/\/cdn.skfmediahub.skf.com\/api\/public\/0901d1968090502d\/png_highpreview_800\/0901d1968090502d_png_highpreview_800.png\" alt=\"skf.com-0901d1968090502d-E-SMS-C\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" \/><\/td>\n<td colspan=\"2\">Control centers can be equipped with SMS messaging devices. In this case, the Maxilube pump unit and control centers can be controlled via SMS messages. Communication is established between the GSM modem of the pump unit or control center and a GSM-enabled mobile phone.<\/td>\n<\/tr>\n<tr>\n<td><strong>Part number<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>12380747<\/strong><\/td>\n<td>E-SMS-C, SMS monitoring and control unit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<div class=\"content-area col-lg-5\">\n<h1 class=\"title title-desktop title-active\"><span style=\"font-size: 16px;\">For single-, dual-line and sequential lubrication systems<\/span><\/h1>\n<div class=\"description\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p>The Maxilube changeover valve is a vital component of dual-line systems used in heavy industry. Over the past decades, it has proven its reliability in a variety of equipment applications in the pulp and paper, metallurgy, and mining industries.<\/p>\n<p>The Maxilube is a compact changeover valve that can also be equipped with an integrated IF-105 control unit. The Maxilube is a pneumatic changeover valve and is an essential component of a pumping station, along with a drum pump unit (MPB or other) and an air pressure regulator. It is often used in dual-line systems, but can also be installed in single-line and sequential lubrication systems. The Maxilube valve can be controlled using a variety of devices, such as the integrated IF-105 control unit or an external control unit.\u00a0<a title=\"ST-2240-LUB\" href=\"https:\/\/www.skf.com\/kz\/products\/lubrication-management\/system-components\/control-units-software\/st-2240-lub\">ST-2240-LUB<\/a>\u00a0or the customer&#039;s distributed control system. Optionally, the Maxilube valve can be monitored using an external control unit using SMS technology.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"columns\">\n<div class=\"column-one\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p class=\"small-capital-heading\">Features and Benefits<\/p>\n<ul>\n<li>Reliable, uninterrupted operation<\/li>\n<li>Suitable for lubricants up to and including NLGI grade 2<\/li>\n<li>Available with integrated control unit IF-105<\/li>\n<li>Compact, robust and reliable design<\/li>\n<li>Suitable for use in oil spray systems<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"column-two\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p class=\"small-capital-heading\">Application areas<\/p>\n<ul>\n<li>Heavy industry<\/li>\n<li>Pulp and paper industry<\/li>\n<li>Mining and metallurgy<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"activity-area col-lg-3\">\n<div class=\"d-flex flex-wrap button-wrapper\">\n<div class=\"card-header\">\n<h5 class=\"mb-0 d-inline-flex\">Brochures and manuals<\/h5>\n<\/div>\n<div class=\"card-body\">\n<div class=\"card-text\">\n<div class=\"list-group list-group-flush\">\n<div class=\"link-group-title\"><i class=\"icon-related-pdf\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/2-1.pdf\">\u00a0Product brochure (74.2 KB)<\/a><\/div>\n<div class=\"link-group-title\"><i class=\"icon-related-pdf\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/2.1.pdf\">\u00a0Operating and maintenance instructions (2.1 MB)<\/a><\/div>\n<div class=\"link-group-title\"><i class=\"icon-related-pdf\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/2.2.pdf\">\u00a0Dualset valve (145.6 KB)<\/a><\/div>\n<div class=\"link-group-title\"><i class=\"icon-related-pdf\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/2.3.pdf\">\u00a0Operation and Maintenance Instructions - IF-105 User Interface (260.4 KB)<\/a><\/div>\n<div class=\"link-group-title\"><i class=\"icon-related-pdf\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/2.4.pdf\">\u00a0SKF Maxilube (501.5 KB)<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"featured_media":6784,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[11523],"product_tag":[],"class_list":{"0":"post-6794","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ustrojstva-monitoringa","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product\/6794","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media\/6784"}],"wp:attachment":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media?parent=6794"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_brand?post=6794"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_cat?post=6794"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_tag?post=6794"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}