{"id":6746,"date":"2025-02-12T13:11:37","date_gmt":"2025-02-12T10:11:37","guid":{"rendered":"https:\/\/titan.ziz.kz\/?post_type=product&#038;p=6746"},"modified":"2025-07-01T11:47:53","modified_gmt":"2025-07-01T08:47:53","slug":"mehanicheskaja-sistema-dlja-predotvrashhenija-perepolnenija-rezervuarov","status":"publish","type":"product","link":"https:\/\/tpgt.kz\/en\/product\/mehanicheskaja-sistema-dlja-predotvrashhenija-perepolnenija-rezervuarov\/","title":{"rendered":"Mechanical system to prevent tank overfilling"},"content":{"rendered":"<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<p>Operating principle<\/p>\n<div class=\"videoContainer\">\n<div id=\"video-f813053d-7aef-4daa-b7ef-bb7a59c7348b\" class=\"smh-player\" data-attached=\"true\"><iframe id=\"widget2\" title=\"SKF offers new Lincoln grease overflow prevention system\" data-src=\"https:\/\/www.youtube.com\/embed\/TsOxPJQ3y8E?playsinline=1&amp;enablejsapi=1&amp;origin=https%3A%2F%2Fwww.skf.com&amp;widgetid=1\" width=\"640\" height=\"360\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\" data-gtm-yt-inspected-116205449_31=\"true\" data-gtm-yt-inspected-116205449_53=\"true\" data-gtm-yt-inspected-116205449_58=\"true\" data-mce-fragment=\"1\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" data-load-mode=\"1\"><\/iframe><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-492133\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"part numbers\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Technical specifications<\/caption>\n<colgroup>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"40%\" valign=\"top\" \/>\n<col width=\"40%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td>Operating temperature<\/td>\n<td>from \u221240 to +65.5 \u00b0C<\/td>\n<td><em>from \u221240 to +150 \u00b0F<\/em><\/td>\n<\/tr>\n<tr>\n<td>Working pressure<\/td>\n<td>517 bar<\/td>\n<td><em>7500 psi<\/em><\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td colspan=\"2\">High-strength steel with anti-corrosion coating<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-492132\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"Factory Installation Ordering Guide\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Factory Installation Ordering Guide<\/caption>\n<colgroup>\n<col width=\"15%\" valign=\"top\" \/>\n<col width=\"15%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"10%\" valign=\"top\" \/>\n<col width=\"10%\" valign=\"top\" \/>\n<col width=\"10%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Order numbers<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<td><strong>Nutrition<\/strong><\/td>\n<td colspan=\"2\"><strong>Tank capacity<\/strong><\/td>\n<td><strong>Level sensor<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr>\n<td><strong>FlowMaster without mechanical shut-off valve<\/strong><\/td>\n<td><strong>FlowMaster with mechanical shut-off valve\u00a0<sup class=\"footnote\">1)<\/sup><\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td>pounds<\/td>\n<td><em>kg<\/em><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>85728<\/td>\n<td><strong>85728MSO<\/strong><\/td>\n<td rowspan=\"7\">FlowMaster electric pump with mechanical shut-off valve and reservoir<\/td>\n<td>24 VDC<\/td>\n<td>60<\/td>\n<td><em>27<\/em><\/td>\n<td>Mechanical<\/td>\n<\/tr>\n<tr>\n<td>85712<\/td>\n<td><strong>85712MSO<\/strong><\/td>\n<td>24 VDC<\/td>\n<td>60<\/td>\n<td>27<\/td>\n<td>Not applicable<\/td>\n<\/tr>\n<tr>\n<td>85763<\/td>\n<td><strong>85763MSO<\/strong><\/td>\n<td>24 VDC<\/td>\n<td>60<\/td>\n<td>27<\/td>\n<td>Magnetic<\/td>\n<\/tr>\n<tr>\n<td>85729<\/td>\n<td><strong>85729MSO<\/strong><\/td>\n<td>24 VDC<\/td>\n<td>90<\/td>\n<td><em>41<\/em><\/td>\n<td>Mechanical<\/td>\n<\/tr>\n<tr>\n<td>85762<\/td>\n<td><strong>85762MSO<\/strong><\/td>\n<td>24 VDC<\/td>\n<td>90<\/td>\n<td><em>41<\/em><\/td>\n<td>Magnetic<\/td>\n<\/tr>\n<tr>\n<td>85730<\/td>\n<td><strong>85730MSO<\/strong><\/td>\n<td>24 VDC<\/td>\n<td>120<\/td>\n<td><em>54<\/em><\/td>\n<td>Mechanical<\/td>\n<\/tr>\n<tr>\n<td>85878<\/td>\n<td><strong>85878MSO<\/strong><\/td>\n<td>24 VDC<\/td>\n<td>120<\/td>\n<td><em>54<\/em><\/td>\n<td>Mechanical, magnetic<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\"><\/td>\n<\/tr>\n<tr>\n<td>85722<\/td>\n<td><strong>85722MSO<\/strong><\/td>\n<td rowspan=\"3\">FlowMaster hydraulic pump with mechanical shut-off valve and reservoir<\/td>\n<td>Hydraulic<\/td>\n<td>60<\/td>\n<td><em>27<\/em><\/td>\n<td>Mechanical<\/td>\n<\/tr>\n<tr>\n<td>85725<\/td>\n<td><strong>85725MSO<\/strong><\/td>\n<td>Hydraulic<\/td>\n<td>90<\/td>\n<td><em>41<\/em><\/td>\n<td>Mechanical<\/td>\n<\/tr>\n<tr>\n<td>85727<\/td>\n<td><strong>85727MSO<\/strong><\/td>\n<td>Hydraulic<\/td>\n<td>120<\/td>\n<td><em>54<\/em><\/td>\n<td>Mechanical<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\"><\/td>\n<\/tr>\n<tr>\n<td>84050<\/td>\n<td><strong>84050MSO<\/strong><\/td>\n<td rowspan=\"2\">Pneumatic drum pump with mechanical shut-off valve and reservoir<\/td>\n<td>Pneumatic<\/td>\n<td>60<\/td>\n<td><em>27<\/em><\/td>\n<td>Not applicable<\/td>\n<\/tr>\n<tr>\n<td>85460<\/td>\n<td><strong>85460MSO<\/strong><\/td>\n<td>Pneumatic<\/td>\n<td>90<\/td>\n<td><em>41<\/em><\/td>\n<td>Mechanical<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"List of parts for modernization\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>List of parts for modernization - required parts<\/caption>\n<colgroup>\n<col width=\"15%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"25%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td><strong>Order numbers<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<td><strong>Suitable for<\/strong><\/td>\n<td colspan=\"2\"><strong>Tank capacity<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>pounds<\/td>\n<td><em>kg<\/em><\/td>\n<\/tr>\n<tr>\n<td><strong>279197<\/strong><\/td>\n<td>Pivot arm assembly<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>278668<\/strong><\/td>\n<td>Mechanical shut-off valve, 1\/2&quot; NPT ports<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>279590<\/strong><\/td>\n<td>Supply pipeline safety valve<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\"><\/td>\n<\/tr>\n<tr>\n<td><strong>279595<\/strong><\/td>\n<td>Barrel lid\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>Electric pumps FlowMaster, FlowMaster I, Flowmaster II<br \/>\nPneumatic barrel pumps<\/td>\n<td>60 \/ 90<\/td>\n<td><em>27 \/ 41<\/em><\/td>\n<\/tr>\n<tr>\n<td><strong>279596<\/strong><\/td>\n<td>Barrel lid\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>Hydraulic pumps FlowMaster, FlowMaster I, Flowmaster II<\/td>\n<td>60 \/ 90<\/td>\n<td><em>27 \/ 41<\/em><\/td>\n<\/tr>\n<tr>\n<td><strong>279594<\/strong><\/td>\n<td>Barrel lid\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>Hydraulic and electric pumps FlowMaster, FlowMaster I, Flowmaster II<br \/>\nPneumatic barrel pumps<\/td>\n<td>120<\/td>\n<td><em>54<\/em><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\"><\/td>\n<\/tr>\n<tr>\n<td><strong>249355<\/strong><\/td>\n<td>Drum lid sealing gasket\u00a0<sup class=\"footnote\">3)<\/sup><\/td>\n<td>Hydraulic and electric pumps FlowMaster, FlowMaster I, Flowmaster II<br \/>\nPneumatic barrel pumps<\/td>\n<td>60 \/ 90<\/td>\n<td><em>27 \/ 41<\/em><\/td>\n<\/tr>\n<tr>\n<td><strong>271944<\/strong><\/td>\n<td>Drum lid sealing gasket\u00a0<sup class=\"footnote\">3)<\/sup><\/td>\n<td>Hydraulic and electric pumps FlowMaster, FlowMaster I, Flowmaster II<br \/>\nPneumatic barrel pumps<\/td>\n<td>120<\/td>\n<td><em>54<\/em><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\"><\/td>\n<\/tr>\n<tr>\n<td><strong>276496<\/strong><\/td>\n<td>Pressure plate kits<\/td>\n<td>Electric or hydraulic pumps FlowMaster, FlowMaster I<\/td>\n<td>60 \/ 90<\/td>\n<td><em>27 \/41<\/em><\/td>\n<\/tr>\n<tr>\n<td><strong>278094<\/strong><\/td>\n<td>Pressure plate kits<\/td>\n<td>Electric or hydraulic pumps FlowMaster, FlowMaster I<\/td>\n<td>120<\/td>\n<td><em>54<\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"List of parts for modernization\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>List of parts for modernization - options<\/caption>\n<colgroup>\n<col width=\"15%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"25%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td><strong>Order numbers<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<td><strong>Suitable for<\/strong><\/td>\n<td colspan=\"2\"><strong>Tank capacity<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<tbody>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>pounds<\/td>\n<td><em>kg<\/em><\/td>\n<\/tr>\n<tr>\n<td><strong>279608<\/strong><\/td>\n<td>Supply line relief valve, 1\/4 turn, spring loaded<\/td>\n<td>Used instead of 279590<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\"><\/td>\n<\/tr>\n<tr>\n<td><strong>278092<\/strong><\/td>\n<td>Magnetic level sensor<\/td>\n<td>Flat pressure plates on FlowMaster and FlowMaster I pumps and<br \/>\npneumatic barrel pumps<\/td>\n<td>90 \/ 120<\/td>\n<td><em>41 \/ 54<\/em><\/td>\n<\/tr>\n<tr>\n<td><strong>277654<\/strong><\/td>\n<td>Magnetic level sensor<\/td>\n<td>2&quot; (51mm) foam pressure plates on FlowMaster II and<br \/>\npneumatic barrel pumps<\/td>\n<td>90 \/ 120<\/td>\n<td><em>41 \/ 54<\/em><\/td>\n<\/tr>\n<tr>\n<td><strong>277659<\/strong><\/td>\n<td>Magnetic level sensor<\/td>\n<td>2&quot; (51mm) foam pressure plates on FlowMaster II and<br \/>\npneumatic barrel pumps<\/td>\n<td>60<\/td>\n<td><em>27<\/em><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\"><\/td>\n<\/tr>\n<tr>\n<td><strong>279614<\/strong><\/td>\n<td colspan=\"4\">Magnetic Bracket Kit for Level Sensor<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\"><\/td>\n<\/tr>\n<tr>\n<td><strong>279558<\/strong><\/td>\n<td colspan=\"4\">High-pressure quick-disconnect couplings - coupling, female thread 3\/8 NPT<\/td>\n<\/tr>\n<tr>\n<td><strong>279559<\/strong><\/td>\n<td colspan=\"4\">High-pressure quick-release couplings - nipple, female thread 3\/8 NPT<\/td>\n<\/tr>\n<tr>\n<td><strong>279557<\/strong><\/td>\n<td colspan=\"4\">Upgrade kit - hose from outlet valve to pump\u00a0<sup class=\"footnote\">4)<\/sup><\/td>\n<\/tr>\n<tr>\n<td><strong>279613<\/strong><\/td>\n<td colspan=\"4\">Drum lid locking plate kit for level sensor\u00a0<sup class=\"footnote\">5)<\/sup><\/td>\n<\/tr>\n<tr>\n<td><strong>276892<\/strong><\/td>\n<td colspan=\"4\">Level sensor pressure plate locking pad kit\u00a0<sup class=\"footnote\">5)<\/sup><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"footer\">\n<ol>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>1)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Other configurations are available on request, the supply line safety valve is not included in the scope of delivery (see list of options)<\/div>\n<\/div>\n<\/li>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>2)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Select one barrel lid<\/div>\n<\/div>\n<\/li>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>3)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Select one sealing gasket for the barrel lid<\/div>\n<\/div>\n<\/li>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>4)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Required if hose assembly is not available.<\/div>\n<\/div>\n<\/li>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>5)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Required if upgrade kit does not use level sensor.<\/div>\n<\/div>\n<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<div class=\"content-area col-lg-5\">\n<h1 class=\"title title-desktop title-active\"><span style=\"font-size: 16px;\">Preventing risks associated with tank overfilling<\/span><\/h1>\n<div class=\"description\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p>Lincoln&#039;s mechanical overfill prevention system improves worker safety by eliminating the risks associated with tank overfills. It also reduces environmental risks associated with potential leaks.<\/p>\n<p>The system is easy to install and operate, eliminating the need for staff to constantly fill the tank, freeing up time for other tasks. Since the system is mechanical, it requires no electricity to operate.<\/p>\n<p>The mechanical overfill prevention system is compatible with any pump that uses a Lincoln FlowMaster reservoir. It&#039;s available as a factory-installed system or as an optional upgrade.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"columns\">\n<div class=\"column-one\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p class=\"small-capital-heading\">Technical characteristics and advantages<\/p>\n<ul>\n<li>To simplify ordering, models with factory-installed FlowMaster pumps are available.<\/li>\n<li>Improved worker safety by preventing leaks that can cause slips and falls, reducing the risk of fires and other hazards<\/li>\n<li>Reducing the number of tank filling personnel<\/li>\n<li>No additional cleaning procedures or potential fines<\/li>\n<li>The device does not require electricity to operate as it is mechanical.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"column-two\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p class=\"small-capital-heading\">Application areas<\/p>\n<ul>\n<li>Grease filling processes<\/li>\n<li>Can be used with a wide range of feed\/filling pumps<\/li>\n<li>Compatible with any pump when using FlowMaster reservoirs<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"activity-area col-lg-3\">\n<h3 class=\"d-flex flex-wrap button-wrapper\">Documentation<\/h3>\n<div class=\"link-group-title\"><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/07\/212.pdf\">\u00a0Product brochure (414.9 KB)<\/a><\/div>\n<div><\/div>\n<\/div>","protected":false},"featured_media":6755,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[11523],"product_tag":[],"class_list":{"0":"post-6746","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ustrojstva-monitoringa","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product\/6746","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media\/6755"}],"wp:attachment":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media?parent=6746"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_brand?post=6746"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_cat?post=6746"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_tag?post=6746"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}