{"id":6107,"date":"2025-02-10T16:55:29","date_gmt":"2025-02-10T13:55:29","guid":{"rendered":"https:\/\/titan.ziz.kz\/?post_type=product&#038;p=6107"},"modified":"2025-08-06T15:34:11","modified_gmt":"2025-08-06T12:34:11","slug":"shesterjonnyj-nasosnyj-agregat-mfe-s-jelektricheskim-privodom","status":"publish","type":"product","link":"https:\/\/tpgt.kz\/en\/product\/shesterjonnyj-nasosnyj-agregat-mfe-s-jelektricheskim-privodom\/","title":{"rendered":"MFE gear pump unit with electric drive"},"content":{"rendered":"<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-483255\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"Technical data\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Technical specifications<\/caption>\n<colgroup>\n<col width=\"40%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td>Operating principle<\/td>\n<td colspan=\"2\">Electric driven gear pump<\/td>\n<\/tr>\n<tr>\n<td>Lubricant<\/td>\n<td colspan=\"2\">mineral or synthetic oil, from 20 to 850 mm\u00b2\/s<br \/>\nliquid lubricant NLGI 000 or 00<\/td>\n<\/tr>\n<tr>\n<td>Number of lubricant outlets<\/td>\n<td colspan=\"2\">1<\/td>\n<\/tr>\n<tr>\n<td>Dosage volume<\/td>\n<td>350\u2013500 cm\u00b3\/min<\/td>\n<td><em>15\u201331 in\u00b3\/min<\/em><\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>from \u221210 to +60 \u00b0C<\/td>\n<td><em>from +14 to +140 \u00b0F<\/em><\/td>\n<\/tr>\n<tr>\n<td>Back pressure<\/td>\n<td>max 17.5; 28 bar<\/td>\n<td><em>max 255; 405 psi<\/em><\/td>\n<\/tr>\n<tr>\n<td>Tank capacity<\/td>\n<td>3; 6 or 15 l<\/td>\n<td><em>0.8; 1.6 or 4 gallons<\/em><\/td>\n<\/tr>\n<tr>\n<td>Material (tank)<\/td>\n<td colspan=\"2\">plastic, metal<\/td>\n<\/tr>\n<tr>\n<td>Output connection<\/td>\n<td colspan=\"2\">M 14\u00d71.5<\/td>\n<\/tr>\n<tr>\n<td>Protection class<\/td>\n<td colspan=\"2\">IP 54<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Dimensions depending on the tank<\/td>\n<\/tr>\n<tr>\n<td align=\"right\">3 l;\u00a0<em>0.8 gallons<\/em>, plastic<\/td>\n<td>303 \u00d7 130 \u00d7 245 mm<\/td>\n<td><em>11.9 x 5.1 x 9.6 inches<\/em><\/td>\n<\/tr>\n<tr>\n<td align=\"right\">3 l;\u00a0<em>0.8 gallons<\/em>, metal<\/td>\n<td>332 \u00d7 178 \u00d7 312 mm<\/td>\n<td><em>13 x 7 x 12.3 inches<\/em><\/td>\n<\/tr>\n<tr>\n<td align=\"right\">6 l;\u00a0<em>1.5 gallons<\/em>, plastic<\/td>\n<td>319 \u00d7 128 \u00d7 265 mm<\/td>\n<td><em>12.6 x 5 x 10.4 inches<\/em><\/td>\n<\/tr>\n<tr>\n<td align=\"right\">6 l;\u00a0<em>1.5 gallons<\/em>, metal<\/td>\n<td>370 \u00d7 167 \u00d7 330 mm<\/td>\n<td><em>14.6 x 6.6 x 12.9 inches<\/em><\/td>\n<\/tr>\n<tr>\n<td align=\"right\">15 l;\u00a0<em>4 gallons<\/em>, metal<\/td>\n<td>453 \u00d7 200 \u00d7 436 mm<\/td>\n<td><em>17.8 x 7.8 x 17.2 inches<\/em><\/td>\n<\/tr>\n<tr>\n<td>Installation position<\/td>\n<td colspan=\"2\">vertical<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"Technical data\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Float switch for low oil level monitoring<\/caption>\n<colgroup>\n<col width=\"40%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td>Contact type<\/td>\n<td colspan=\"2\">1 changeover; 2 changeover contacts (reed contacts)<\/td>\n<\/tr>\n<tr>\n<td>Switching voltage<\/td>\n<td colspan=\"2\">max 230V AC, 230V DC<\/td>\n<\/tr>\n<tr>\n<td>Switching current<\/td>\n<td colspan=\"2\">max 0.8 A; 1.0 A<\/td>\n<\/tr>\n<tr>\n<td>Switching capacity<\/td>\n<td colspan=\"2\">max 60 VA, 40 W<\/td>\n<\/tr>\n<tr>\n<td>Body type<\/td>\n<td colspan=\"2\">IP 65<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-483254\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"order information\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Ordering Information - Oil Pump Units<\/caption>\n<colgroup>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"10%\" valign=\"top\" \/>\n<col width=\"10%\" valign=\"top\" \/>\n<col width=\"15%\" valign=\"top\" \/>\n<col width=\"45%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td><strong>Part number<\/strong><\/td>\n<td colspan=\"2\"><strong>Tank<\/strong><\/td>\n<td><strong>Material<\/strong><\/td>\n<td><strong>Type<\/strong>\u00a0<sup class=\"footnote\">1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>l<\/td>\n<td><em>gallons<\/em><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-K3-2<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version without level control<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW3-2<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version with minimum fill level switch<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW3-2-S4<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version with minimum fill level switch, incl. early warning<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW3-S37+1FV<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>UL\/CSA design with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW3-S35+1FW<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>CCC version with filling level monitoring, including early warning of minimum filling level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW3-S24+MPG\u00a0<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>CE version with 6-pin Harting connector with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-K6<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version without level control<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW6<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version with minimum fill level switch<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW6-S1<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version with minimum fill level switch, incl. early warning<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW6-S42+1FV<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>UL\/CSA design with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW6-S102+1FW<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>CCC version with filling level monitoring, including early warning of minimum filling level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-KW6-S33+MPG<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>CE version with 6-pin Harting connector with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-B3-2<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Metal<\/td>\n<td>Basic CE version without level control<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW3-2<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Metal<\/td>\n<td>Basic CE version with minimum fill level switch<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW3-2-S28<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Metal<\/td>\n<td>Basic CE version with minimum fill level switch, incl. early warning<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW3-S-S34+1FV<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Metal<\/td>\n<td>UL\/CSA listed with fill level monitoring, including low fill level early warning<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW3-S41+MPG<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Metal<\/td>\n<td>CE version with 6-pin Harting connector with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-B7<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Metal<\/td>\n<td>Basic CE version without level control<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW7<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Metal<\/td>\n<td>Basic CE version with minimum fill level switch<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW7-S22+1FV<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Metal<\/td>\n<td>UL\/CSA listed with fill level monitoring, including low fill level early warning<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW7-S97+1FW<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Metal<\/td>\n<td>CCC version with filling level monitoring, including early warning of minimum filling level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW7-S107+MPG<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Metal<\/td>\n<td>CE version with 6-pin Harting connector with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW7-S222+MPG<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Metal<\/td>\n<td>CE version with pressure gauge and dirt filter, with 6-pin Harting connector with filling level monitoring, including early warning of minimum filling level<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW16<\/strong><\/td>\n<td>15<\/td>\n<td><em>4<\/em><\/td>\n<td>Metal<\/td>\n<td>Basic CE version with minimum fill level switch, incl. early warning<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW16-S145+1FV<\/strong><\/td>\n<td>15<\/td>\n<td><em>4<\/em><\/td>\n<td>Metal<\/td>\n<td>UL\/CSA listed with fill level monitoring, including low fill level early warning<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW16-S96+MPG<\/strong><\/td>\n<td>15<\/td>\n<td><em>4<\/em><\/td>\n<td>Metal<\/td>\n<td>CE version with 6-pin Harting connector with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW16-S222+MPG<\/strong><\/td>\n<td>15<\/td>\n<td><em>4<\/em><\/td>\n<td>Metal<\/td>\n<td>CE version with pressure gauge and dirt filter, with 6-pin Harting connector with filling level monitoring, including early warning of minimum filling level<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW30<\/strong><\/td>\n<td>30<\/td>\n<td><em>8<\/em><\/td>\n<td>Metal<\/td>\n<td>Basic CE version with minimum fill level switch<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW30-S30<\/strong><\/td>\n<td>30<\/td>\n<td><em>8<\/em><\/td>\n<td>Metal<\/td>\n<td>Basic CE version with minimum fill level switch, incl. early warning<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW30-S35+MPG<\/strong><\/td>\n<td>30<\/td>\n<td><em>8<\/em><\/td>\n<td>Metal<\/td>\n<td>CE version with 6-pin Harting connector with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE5-BW30-S222+MPG<\/strong><\/td>\n<td>30<\/td>\n<td><em>8<\/em><\/td>\n<td>Metal<\/td>\n<td>CE version with pressure gauge and dirt filter, with 6-pin Harting connector with filling level monitoring, including early warning of minimum filling level<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"footer\">\n<ol>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>1)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Other designs are available upon request.<\/div>\n<\/div>\n<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-494716\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"order information\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Pump units for liquid lubrication<\/caption>\n<colgroup>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"10%\" valign=\"top\" \/>\n<col width=\"10%\" valign=\"top\" \/>\n<col width=\"15%\" valign=\"top\" \/>\n<col width=\"45%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td><strong>Part number<\/strong><\/td>\n<td colspan=\"2\"><strong>Tank<\/strong><\/td>\n<td><strong>Material<\/strong><\/td>\n<td><strong>Type<\/strong>\u00a0<sup class=\"footnote\">1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>l<\/td>\n<td><em>gallons<\/em><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-K3-2<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version without level control<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-K3F-2<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version with minimum fill level switch<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-KW3F-S13+1FV<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>UL\/CSA version with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-KW3F-S9+MPG<\/strong><\/td>\n<td>3<\/td>\n<td><em>0,8<\/em><\/td>\n<td>Plastic<\/td>\n<td>CE version with 6-pin Harting connector with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" bgcolor=\"#FFFFFF\"><\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-K6F<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version without level control<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-K6F-S2<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version with minimum fill level switch<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-KW6F-S1<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>Basic CE version with minimum fill level switch, incl. early warning<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-KW6F-S37+1FV<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>UL\/CSA version with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-KW6F-S41+1FW<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>CCC version with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<tr>\n<td><strong>MFE2-KW6F-S20+MPG<\/strong><\/td>\n<td>6<\/td>\n<td><em>1,6<\/em><\/td>\n<td>Plastic<\/td>\n<td>CE version with 6-pin Harting connector with fill level monitoring, including early warning of minimum fill level<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<div class=\"content-area col-lg-5\">\n<h1 class=\"title title-desktop title-active\"><span style=\"font-size: 16px;\">For single-line lubrication systems<\/span><\/h1>\n<div class=\"description\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p>The MFE series gear pump units are designed for delivering lubricant in single-line, intermittent lubrication systems. The basic kit includes a gear pump with an electric motor, a 3- or 6-liter metal or plastic lubricant reservoir, or a 15-liter metal reservoir. A float switch can be used to monitor the minimum lubricant level. In addition to the basic models, the units can be equipped with additional accessories.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"columns\">\n<div class=\"column-one\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p class=\"small-capital-heading\">Technical characteristics and advantages<\/p>\n<ul>\n<li>Built-in float switch for filling level monitoring<\/li>\n<li>Built-in safety valve and pressure regulating valve<\/li>\n<li>Electric motors for various voltage ranges and corresponding approvals<\/li>\n<li>Special designs for various applications<\/li>\n<li>Suitable for intermittent operation<\/li>\n<li>For remote installation outside the tank or for an integrated tank<\/li>\n<li>Reliability and versatility<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"column-two\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p class=\"small-capital-heading\">Application areas<\/p>\n<ul>\n<li>Automotive industry<\/li>\n<li>Metallurgy, including presses<\/li>\n<li>Machine tools<\/li>\n<li>Printing and finishing<\/li>\n<li>Industrial assembly and automation<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"activity-area col-lg-3\">\n<div class=\"d-flex flex-wrap button-wrapper\">\n<div class=\"card-header\">\n<h5 class=\"mb-0 d-inline-flex\">Brochures and manuals<\/h5>\n<\/div>\n<div class=\"card-body\">\n<div class=\"card-text\">\n<div class=\"list-group list-group-flush\">\n<div class=\"link-group-title\"><i class=\"icon-related-pdf\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/129.pdf\">Product brochure (622.0 KB)<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"featured_media":6110,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[11519],"product_tag":[],"class_list":{"0":"post-6107","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nasosy-i-nasosnye-agregaty","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product\/6107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media\/6110"}],"wp:attachment":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media?parent=6107"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_brand?post=6107"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_cat?post=6107"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_tag?post=6107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}