{"id":6070,"date":"2025-02-10T15:03:54","date_gmt":"2025-02-10T12:03:54","guid":{"rendered":"https:\/\/titan.ziz.kz\/?post_type=product&#038;p=6070"},"modified":"2025-08-05T14:21:55","modified_gmt":"2025-08-05T11:21:55","slug":"nasosnyj-agregat-kfg-s-jelektricheskim-privodom","status":"publish","type":"product","link":"https:\/\/tpgt.kz\/en\/product\/nasosnyj-agregat-kfg-s-jelektricheskim-privodom\/","title":{"rendered":"KFG pumping unit with electric drive"},"content":{"rendered":"<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-481276\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"Technical specifications\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Technical specifications<\/caption>\n<colgroup>\n<col width=\"40%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td>Operating principle<\/td>\n<td colspan=\"2\" align=\"left\">electrically driven piston pump<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature range\u00a0<sup class=\"footnote\">1)<\/sup><\/td>\n<td>from -30 to +70 \u00b0C<\/td>\n<td><em>from -22 to +158 \u00b0F<\/em><\/td>\n<\/tr>\n<tr>\n<td>Working pressure\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>200\u2013300 bar<\/td>\n<td><em>2900-4350 psi<\/em><\/td>\n<\/tr>\n<tr>\n<td>Lubricant<\/td>\n<td colspan=\"2\">grease NLGI from 000 to 2<br \/>\ncompatible with plastics, butadiene acrylonitrile rubber, copper and copper alloys<\/td>\n<\/tr>\n<tr>\n<td>Outlet pipes<\/td>\n<td colspan=\"2\">from 1 to 3<\/td>\n<\/tr>\n<tr>\n<td>Dosing volume per pump element<\/td>\n<td>0.8; 1.3; 1.8; 2.5; 5.0 cm\u00b3\/min<\/td>\n<td><em>0.049; 0.079, 0.11, 0.15, 0.31 in\u00b3\/min<\/em><\/td>\n<\/tr>\n<tr>\n<td>Tank<\/td>\n<td>2; 4; 6; 8; 10; 12; 15; 20 kg<\/td>\n<td><em>4.4; 8.8; 13.2; 17.6; 22; 26.5; 33; 44 pounds<\/em><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Material<\/td>\n<\/tr>\n<tr>\n<td align=\"right\">pump body<\/td>\n<td colspan=\"2\">aluminum-silicon alloy<\/td>\n<\/tr>\n<tr>\n<td align=\"right\">tank<\/td>\n<td colspan=\"2\">polyamide PA 6I, PMMA<\/td>\n<\/tr>\n<tr>\n<td>Connection of the main pipeline<\/td>\n<td colspan=\"2\">M 14 \u00d7 1.5 with internal thread<\/td>\n<\/tr>\n<tr>\n<td>power unit<\/td>\n<td colspan=\"2\">12\/24 VDC,<br \/>\n230 (100\u2013273) VAC; (\u00b110 %)<\/td>\n<\/tr>\n<tr>\n<td>Protection class<\/td>\n<td colspan=\"2\">IP56<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Dimensions<\/td>\n<\/tr>\n<tr>\n<td align=\"right\">min.<\/td>\n<td>266 \u00d7 208 \u00d7 229 mm<\/td>\n<td><em>10.47 x 8.19 x 9.01 inches<\/em><\/td>\n<\/tr>\n<tr>\n<td align=\"right\">Max.<\/td>\n<td>268 \u00d7 227 \u00d7 1170 mm<\/td>\n<td><em>10.55 x 8.93 x 46.06 inches<\/em><\/td>\n<\/tr>\n<tr>\n<td>Installation position<\/td>\n<td colspan=\"2\">with pressure plate: any, including rotation conditions<br \/>\nwithout pressure plate: vertical<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"footer\">\n<ol>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>1)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Depending on the pump element<\/div>\n<\/div>\n<\/li>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>2)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Depending on the type and size of the pump element<\/div>\n<\/div>\n<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-489813\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<table class=\"no-colors\" title=\"Sample order\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Sample order<\/caption>\n<colgroup>\n<col width=\"30%\" valign=\"top\" \/>\n<col width=\"70%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td colspan=\"2\">The product can be configured using a configuration code. The applicable part number and explanation are provided in the order sample.<\/td>\n<\/tr>\n<tr>\n<td><strong>KFGS3FXXAXXDEB+924<\/strong><\/td>\n<td>\n<ul>\n<li>KFG piston pump unit<\/li>\n<li>Control unit IG502-2-I<\/li>\n<li>Tank 6 kg<\/li>\n<li>Application in vehicles<\/li>\n<li>Without filling with lubricant<\/li>\n<li>Without filling level control<\/li>\n<li>The feed rate of the pump element with a spring return piston on the outlet pipe 1: 2.5 cm<sup>3<\/sup>\/min<\/li>\n<li>Fitting on the outlet pipe, 8 mm<\/li>\n<li>Factory settings of the control unit<\/li>\n<li>System voltage 24VDC<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">You can configure your product using the CAD configurator below. This will provide you with a specific order number.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-506335\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<h3>Accessories<\/h3>\n<\/div>\n<\/div>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p>Pump elements deliver lubricant to lubrication points or distributors via lubrication lines. Five pump elements for flow rates from 0.8 to 5.0 cm\u00b3\/min are available in two designs: with a spring-return piston or with a positively driven piston. In many cases, a pump element with a spring-return piston is the right choice. The pump element with a positively driven piston was designed for use in extremely cold conditions (down to -30 \u00b0C) or for handling high-viscosity lubricants. Up to three pump elements can be installed in a KFG pump unit. Possible mounting locations are the left, front, and right sides of the pump housing. The lubricant outlet on the pump element has an internal M14x1.5 thread for connecting lubrication lines or valves. If a pump element is not installed, the outlet on the pump housing is closed with a screw.<\/p>\n<table class=\"no-colors\" title=\"spare parts\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Pump elements<\/caption>\n<colgroup>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/>\n<col width=\"20%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td><\/td>\n<td><strong>Part number<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<td colspan=\"2\"><strong>Nominal performance<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><\/td>\n<td>cm<sup>3<\/sup>\/min<\/td>\n<td><em>inches<sup>3<\/sup>\/min<\/em><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>KFG1.U0<\/strong>\u00a0<sup class=\"footnote\">1)<\/sup><\/td>\n<td>pump element with a spring-return piston<\/td>\n<td>5,0<\/td>\n<td><em>0,31<\/em><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>KFG1.U1\u00a0<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>pump element with a spring-return piston<\/td>\n<td>2,5<\/td>\n<td><em>0,15<\/em><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>KFG1.U2\u00a0<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>pump element with a spring-return piston<\/td>\n<td>1,8<\/td>\n<td><em>0,11<\/em><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#FFFFFF\"><img decoding=\"async\" title=\"KFG1_U3\" data-src=\"https:\/\/cdn.skfmediahub.skf.com\/api\/public\/0901d1968090b9d8\/png_highpreview_800\/0901d1968090b9d8_png_highpreview_800.png\" alt=\"KFG1_U3\" width=\"300\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" \/><\/td>\n<td><strong>KFG1.U3<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>pump element with a spring-return piston<\/td>\n<td>1,3<\/td>\n<td><em>0,079<\/em><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>KFG1.U4\u00a0<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>pump element with a spring-return piston<\/td>\n<td>0,8<\/td>\n<td><em>0,049<\/em><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>KFG1.U0-E\u00a0<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>pump element with a positively driven piston<\/td>\n<td>5,0<\/td>\n<td><em>0,31<\/em><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>KFG1.U1-E\u00a0<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>pump element with a positively driven piston<\/td>\n<td>2,5<\/td>\n<td><em>0,15<\/em><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>KFG1.U2-E\u00a0<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>pump element with a positively driven piston<\/td>\n<td>1,8<\/td>\n<td><em>0,11<\/em><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>KFG1.U3-E\u00a0<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>pump element with a positively driven piston<\/td>\n<td>1,3<\/td>\n<td><em>0,079<\/em><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"footer\">\n<ol>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>1)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Max. working pressure 200 bar \/\u00a0<em>2900 psi<\/em><\/div>\n<\/div>\n<\/li>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>2)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Max. working pressure 300 bar \/<em>4850 psi<\/em><\/div>\n<\/div>\n<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-506342\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p>To prevent excessive operating pressure, a rotary relief valve must be installed in the system. If the operating pressure exceeds the pressure relief valve&#039;s operating point, the valve opens, allowing the lubricant to escape. Pressure relief valves are primarily used in progressive systems. Options are available with SKF quick-release couplings, straight connectors, and G 1\/4&quot; female threads.<\/p>\n<table class=\"no-colors\" title=\"Technical data\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Safety valves<\/caption>\n<colgroup>\n<col width=\"40%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/>\n<col width=\"30%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td><strong>Order number<\/strong><\/td>\n<td><strong>Compound<\/strong><\/td>\n<td><strong>Pipeline, \u2205<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-063<\/strong>\u00a0<sup class=\"footnote\">1)<\/sup><\/td>\n<td>direct connection<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-061<\/strong>\u00a0<sup class=\"footnote\">1)<\/sup><\/td>\n<td>SKF quick release coupling<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-065<\/strong>\u00a0<sup class=\"footnote\">1)<\/sup><\/td>\n<td>direct connection<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-062<\/strong>\u00a0<sup class=\"footnote\">1)<\/sup><\/td>\n<td>direct connection<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-012<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>direct connection<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-024<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>direct connection<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-066<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>direct connection<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-021<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>SKF quick release coupling<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-034<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>SKF quick release coupling<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td><strong>161-210-036<\/strong>\u00a0<sup class=\"footnote\">2)<\/sup><\/td>\n<td>internal thread G 1\/4<\/td>\n<td>&#8212;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"footer\">\n<ol>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>1)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Max. working pressure 200 bar \/\u00a0<em>2900 psi<\/em><\/div>\n<\/div>\n<\/li>\n<li class=\"d-flex\"><span class=\"mr-1\"><sup>2)<\/sup><\/span>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">Max. working pressure 300 bar \/<em>4850 psi<\/em><\/div>\n<\/div>\n<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-506343\" class=\"body-text-main col-md-8 space-between\">\n<div class=\"body-text-main\">\n<div class=\"body\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p>One of the pump&#039;s three lubricant outlets can be optionally equipped with a single matching filling nozzle instead of a single pump element for filling the unit using a filling tank (cartridge). The filling tank can also be used to fill the pump unit through one of the lubricant outlets. To do this, specify a filling nozzle in the order code instead of a lubricant outlet.<\/p>\n<table class=\"no-colors\" title=\"spare parts\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Filling nipple kit<\/caption>\n<colgroup>\n<col width=\"40%\" valign=\"top\" \/>\n<col width=\"60%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td><strong>Part number<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>169-000-174<\/strong><\/td>\n<td>filling nipple<\/td>\n<\/tr>\n<tr>\n<td><strong>169-000-171<\/strong><\/td>\n<td>filling tank<\/td>\n<\/tr>\n<tr>\n<td><strong>24-9909-0241<\/strong><\/td>\n<td>filling socket G 1\/4, set<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p>As an alternative to a cone-head nipple, units for industrial or vehicle applications can also be equipped with a filling port for filling with a filling pump, such as a hand pump with a container. The filling pump must be equipped with a suitable coupling and a hose port.<\/p>\n<table class=\"no-colors\" title=\"spare parts\" border=\"1\" width=\"100%\" cellspacing=\"1\" cellpadding=\"1\">\n<caption>Filling nipple kit<\/caption>\n<colgroup>\n<col width=\"40%\" valign=\"top\" \/>\n<col width=\"60%\" valign=\"top\" \/><\/colgroup>\n<tbody>\n<tr>\n<td><strong>Part number<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>24-9909-0244<\/strong><\/td>\n<td>KFG filling nipple kit, G 1\/4<\/td>\n<\/tr>\n<tr>\n<td><strong>857-760-007<\/strong><\/td>\n<td>hose socket \u2205 13 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>857-870-002<\/strong><\/td>\n<td>socket for hose \u2205 16 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>995-001-500<\/strong><\/td>\n<td>coupling sleeve<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-491916\" class=\"col-md-8 space-between\">\n<p>Configure KFG for industrial applications, download CAD file<\/p>\n<div><iframe id=\"iframe-id-5b67bd56-7045-4302-a5de-f4bcd1c1d5e3\" data-src=\"https:\/\/webapi.partcommunity.com\/23d-libs\/us_configurator\/sa2\/skf\/index.vbb?info=skf_lubrication\/pumpen_pumpenaggregate\/kfg\/2_kfg_industrie_asmtab.prj\" height=\"913\" data-gtm-yt-inspected-116205449_31=\"true\" data-gtm-yt-inspected-116205449_53=\"true\" data-gtm-yt-inspected-116205449_58=\"true\" data-mce-fragment=\"1\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" data-load-mode=\"1\"><\/iframe><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-491917\" class=\"col-md-8 space-between\">\n<p>Configure KFG for rotating assemblies, download CAD file<\/p>\n<div><iframe id=\"iframe-id-83aee8a7-0d66-4eb0-8cd4-56a421acd6c2\" data-src=\"https:\/\/webapi.partcommunity.com\/23d-libs\/us_configurator\/sa2\/skf\/index.vbb?info=skf_lubrication\/pumpen_pumpenaggregate\/kfg\/3_kfg_rotierend_asmtab.prj\" height=\"913\" data-gtm-yt-inspected-116205449_31=\"true\" data-gtm-yt-inspected-116205449_53=\"true\" data-gtm-yt-inspected-116205449_58=\"true\" data-mce-fragment=\"1\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" data-load-mode=\"1\"><\/iframe><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"sections\">\n<div>\n<div class=\"container\">\n<div class=\"row\">\n<div id=\"cid-491918\" class=\"col-md-8 space-between\">\n<p>Configure KFG for mobile use, download CAD file<\/p>\n<div><iframe id=\"iframe-id-0e2dd6c4-5546-40cb-ae7e-9b916e382a24\" data-src=\"https:\/\/webapi.partcommunity.com\/23d-libs\/us_configurator\/sa2\/skf\/index.vbb?info=skf_lubrication\/pumpen_pumpenaggregate\/kfg\/4_kfg_fahrzeug_asmtab.prj\" height=\"913\" data-gtm-yt-inspected-116205449_31=\"true\" data-gtm-yt-inspected-116205449_53=\"true\" data-gtm-yt-inspected-116205449_58=\"true\" data-mce-fragment=\"1\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" data-load-mode=\"1\"><\/iframe><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<h1 class=\"title title-desktop title-active\"><span style=\"font-size: 16px;\">For single-line and sequential lubrication systems<\/span><\/h1>\n<div class=\"description\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p>The KFG electric pump features a drive shaft with an eccentric, which drives up to three pump elements. It consists of four main components: a housing with pump elements, a reservoir with level monitoring, integrated control units, and additional accessories. The pump is available in eight sizes and two versions: for stationary use or with a grease pressure plate, allowing for use in any position. A range of additional accessories allows for reservoir filling, pump protection (pressure relief valve), or simple connection to a centralized lubrication system.<\/p>\n<p>KFG versions are available for use in single-line and progressive lubrication systems.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"columns\">\n<div class=\"column-one\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p class=\"small-capital-heading\">Technical characteristics and advantages<\/p>\n<ul>\n<li>Reliability: thanks to durable materials, robust components and designs for extreme operating conditions (forced-driven pump elements)<\/li>\n<li>Ready-to-use pump design for reduced installation time<\/li>\n<li>For specific application areas: Customised designs thanks to flexible unit configuration options<\/li>\n<li>Versatility: Can be used in single-line and serial systems<\/li>\n<li>Safety: filling level monitoring, lubrication system monitoring, pressure relief and control unit<\/li>\n<li>Options: Top filling, various electronic devices<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"column-two\">\n<div class=\"content text-darker-green-grey\">\n<div id=\"rich-text-div\">\n<p class=\"small-capital-heading\">Application areas<\/p>\n<ul>\n<li>Wind turbines (including rotating assemblies)<\/li>\n<li>Construction equipment<\/li>\n<li>On-road and off-road vehicles<\/li>\n<li>Industry<\/li>\n<\/ul>\n<div class=\"card-header\">\n<h5 class=\"mb-0 d-inline-flex\"><span class=\"ng-star-inserted\">Brochures and manuals<\/span><\/h5>\n<\/div>\n<div class=\"card-body\">\n<div class=\"card-text\">\n<div class=\"list-group list-group-flush ng-star-inserted\">\n<div class=\"link-group-title\"><i class=\"icon-related-pdf ng-star-inserted\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/1.16.pdf\">\u00a0Product catalog\u00a0<span class=\"ng-star-inserted\">(1.5 MB)<\/span><\/a><\/div>\n<div class=\"link-group-title\"><i class=\"icon-related-pdf ng-star-inserted\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/1.17.pdf\">\u00a0Installation Instructions - KFG Grease Plate Pump\u00a0<span class=\"ng-star-inserted\">(6.2 MB)<\/span><\/a><\/div>\n<div class=\"link-group-title\"><i class=\"icon-related-pdf ng-star-inserted\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/1.18.pdf\">\u00a0Installation Instructions - KFG Industrial Pump\u00a0<span class=\"ng-star-inserted\">(3.9 MB)<\/span><\/a><\/div>\n<div class=\"link-group-title\"><i class=\"icon-related-pdf ng-star-inserted\"><\/i><a href=\"https:\/\/tpgt.kz\/wp-content\/uploads\/2025\/08\/1.19.pdf\">\u00a0Installation Instructions - KFG Pump for Vehicle Use\u00a0<span class=\"ng-star-inserted\">(5.7 MB)<\/span><\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"featured_media":6075,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[1613],"product_tag":[],"class_list":{"0":"post-6070","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-motornye-masla","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product\/6070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media\/6075"}],"wp:attachment":[{"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/media?parent=6070"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_brand?post=6070"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_cat?post=6070"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tpgt.kz\/en\/wp-json\/wp\/v2\/product_tag?post=6070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}